P Series Variable Volume Micropipettes

(All sizes $175.00 each + gst, except 5/10ml versions $210.00 each + gst - please specifiy volume required when ordering)

With over 15 years of liquid handling instrument experience, the Topscien engineering and development team set out to design and develop an advanced, next generation pipette. After consulting with more than a hundred researchers and technicians about their evolving requirements, Topscien engineers set their sites on creating an ultra-lightweight, and ergonomic pipettor without any sacrifice in terms of durability, accuracy and precision.

The P Series incorporates many significant features and advantages truly appreciated by today's research laboratories. A unique volume adjustment system reduces the time and inconvenience associated with volume selection. The uniquely positioned volume dial is located above the pipette handle, allowing for easy one handed adjustment with the user's thumb. In addition, the volume display is located on the side of the pipettor that faces the user. Unlike traditional pipettors, the P Series does not require a second hand to rotate the pipettor 180° to observe the display.

All pipettes feature an innovative, asymetrical designed plunger button that can be rotated to match the comfort preference of the user. This button is freely adjustable to rotate continuously between wide setting, resulting in the more traditional feel of a round, larger diameter plunger button, or to a more narrow (thumb shaped) contour preferred by the majority of researchers.

All materials and components were carefully selected to minimize weight and ensure durability and a long service life. Internal components include precision plungers made of stainless steel (2µl to 1000µl models) and PTFE seals. The pipettors have also been designed with service in mind. They are easy to disassemble, and seals are easy to replace. Silicone lubricant is included with each pipettor. Recalibration can be done in the lab - no tools are required and the instruction manual includes full details on how to properly check pipetting accuracy and how to recalibrate if necessary.

The entire pipettor is autoclavable at 121°C and resistant to UV exposure. All pipettes are factory calibrated in accordance with ISO 8655 standards, and include a factory calibration certificate. 

Features :

1/ Large central pipetting button and separate ejection function
2/ True one-handed operation for both right-and left-handers
3/ Completely autoclavable at 121℃ ( 20 min ) volume-change protection
4/ Four Position volume display , always clearly visible Easy Calibration technique- readjustment without Special tools
5/ Changes from factory settings are clearly visible extemally .
6/ Short stroke of only 12.5 mm to reduce the risk of RSI ( Repetitive Strain Injury )
7/ Corrosion-resistant piston and ejector
8/ Colour coded for easy selection of the right tip CE-compliant


P Series Variable Volume Single Channel Micropipette (121℃ autoclavable)
Cat.No.
Code.No.
Volume
μl
Increment
μl
A*≤±%
CV*≤%
8011179
TP1H
0.1-1μl
(0.001ul)
2
1.2
8011180
TP10H
0.5-10μl
(0.01ul)
1
0.5
8011181
TP20H
2-20μl
(0.02ul)
0.8
0.4
8011182
TP100H
10-100μl
(0.1ul)
0.6
0.2
8011183
TP200H
20-200μl
(0.2ul)
0.6
0.2
8011184
TP1000H
100-1000μl
(1ul)
0.6
0.2
8011185
TP5000H
500-5000μl
(5ul)
0.6
0.2
8011186
TP10000H
1000-10000μl
(10ul)
0.6
0.2



Calibrated to deliver (TD. Ex) Error limits according to the nominal capacity (=maximum volume) indicated on the instrument, obtained with instrument and distilled water at equilibrium with ambient temperature at 20℃,and with smooth, steady operation The error limits are within the limits of DIN EN IS0 8655-2. Conformity certified to DIN 12
600.A=Accuracy, CV =Coefficient of variation


CALIBRATION  User calibration
 
All pipettes have already been factory calibrated for aqueous based solutions. If the pipette volume is clearly inaccurate, it must then be adjusted for solutions of different densities and viscosities or different pipette tips. 

Adjustments can be made using the following Easy Calibration method.
1.    Check the volume, & determine actual value.
2.    Remove the label window and the label, push the hook forward, raise it slightly and then pull it back.
3.    Using a paperclip or a pipette tip, remove the protective film, (this protective film can be discarded).
4.    Push the red adjustment slider completely back, raise the volume setting wheel (decoupling) and release the adjustment slider.
5.    Set the adjustment value with the volume setting wheel in the UNLOCK position, set the previously determined actual value.
6.    Push the adjustment slider completely back again, push the volumesetting wheel downward and release the adjustment slider. Re-insert the label and label window.