eFreeChiller box, ice-free and power free!

Ice-Free Cooling Systems

All day ice-free cooling or freezing for a variety of sample tubes and plates

eFreeChillerTM box provides sample cooling or freezing without ice, electricity or batteries. The reusable internal cooling or freezing
CoolEngergizer 
TM
 provides hours of “0 to +4.0℃” cooling or “-22 to -18℃” freezing. eFreeChillerTM box may also be used with dry ice
to create a compact portable workstation for bacteria, virus and proteins.



Features: 

Accommodates thermo conductive ColdBlock sample modules for 0.2ml PCR tube, 8 and 12 strip tubes, 96-well PCR microplates, 1.5 ~ 2.0mL conical centrifuge tubes and 1ml cryogenic vials.
One module of the ColdBlock has a unique built in temperature indicator.
Uniform and consistent well temperature.
ColdBlock module without built in temperature indicator can be autoclaved and cleaned with bleach solution, alcohol or common laboratory detergents.
eFreeChiller box and CoolEngergizer may be cleaned with bleach solution, alcohol or common laboratory detergents.

Each eFreeChiller unit comes with a high performance EVA base, collar, lid, one CoolEnergizer(optional), and one ColdBlock module(optional).


CoolEnergizer Performance:

CoolEnergizer Type

Pre-frozen time

Duration

Lid Closed

Lid Open

0~+4℃

-20 ℃

4 hours

> 14 hours

> 11 hours

-80 ℃

2 hours

Note : 
Remove 0~+4 ℃ CoolEnergizer from the freezer and place on benchtop for approximately 10 minutes. Frost may form on the CoolEnergizer exterior upon removal from the freezer. Freezing CoolEnergizer for less than the specified time will result in decreased cooling duration.

-22 ~ -18 ℃

-80 ℃

4 hours

> 6 hours

> 4 hours

Note :
1. Remove -22~-18 ℃ CoolEnergizer from the freezer and it can be placed onto eFreeChiller base right away. Frost may form on the CoolEnergizer exterior upon removal from the freezer. Freezing CoolEnergizer for less than the specified time will result in decreased cooling duration.
2. Pre-chilled CoolBlock will provide better performace.
3. CoolEnergizer can not be autoclaved.



Using Dry Ice for Maintaining Freezing Samples at -78℃:

Duration

Lid Closed

Lid Open

300~400ml Dry Ice to fill the base

> 5 hours

> 3 hours



ColdBlock Performance:

On the ice

ColdBlock can equilibrate the temp below +4℃ in approximately 90 seconds.

On the dry ice

ColdBlock can drop the temp to -78℃ in approximately 7 minutes.

In liquid nitrogen

ColdBlock (without temp indicator) can drop the temp. to around -140℃ in approximately 15 minutes

ColdBlock Capacity

without temp. indicator

35 places to hold 1.5 ~ 2.0mL conical centrifuge tube or 1.0ml cryogenic vial.

with temp. indicator

30 places to hold 1.5 ~ 2.0mL conical centrifuge tube or 1.0ml cryogenic vial.

Note : 
ColdBlock with built-in temp. indicator can not be placed in liquid nitrogen, and the indicator will only show from -10 ℃ to +10 ℃.



Optional ColdBlock Modules:

 

 

120 well for 0.2ml PCR tube, 8 and 12 strip tubes, 96 well PCR microplates 35 well for 1.5 ~ 2.0ml conical centrifuge tube or 1.0ml cryogenic vial 30 well for 1.5 ~ 2.0ml conical centrifuge tube or 1.0ml cryogenic vial


ColdBlock Performance:

On ice

ColdBlock can equilibrate to temp below +4℃ in approximately 90 seconds.

On dry ice

ColdBlock can drop the temp to -78℃ in approximately 7 minutes.

In liquid nitrogen

ColdBlock (without temp indicator) can drop the temp. to around -140℃ in approximately 15 minutes

ColdBlock Capacity

without temp. indicator

35 places to hold 1.5 ~ 2.0mL conical centrifuge tube or 1.0mL cryogenic vial.

with temp. indicator

30 places to hold 1.5 ~ 2.0mL conical centrifuge tube or 1.0mL cryogenic vial.

Note : 
ColdBlock with built in temp. indicator can not be placed in liquid nitrogen, and the indicator will only show from -10 ℃ to +10 ℃.



Ordering Information:

Item No. Description External Dimension / Weight

EFC-35

Empty EVA box with base, collar and lid

20.2 x 16 x 16.2 cm / 206g

EFC-CCE

CoolEnergizerTM 0~+4 ℃

850g

EFC-FCE

CoolEnergizerTM -22~-18 ℃

850g

EFC-35-TCV1

ColdBlockTM with temp. indicator for 30 x 1.0mL cryogenic vial

1,080g

EFC-35-TCCT15

ColdBlockTM with temp. indicator for 30 x 1.5mL conical centrifuge tube

1,080g

EFC-35-TCCT2

ColdBlockTM with temp. indicator for 30 x 2.0mL conical centrifuge tube

1,080g
EFC-120-TCCT02 ColdBlockTM without temp. indicator for 0.2ml PCR tube, 8 and 12 strip tubes, and 96-well PCR microplates 1,080g

EFC-35-CV1

ColdBlockTM without temp. indicator for 35 x 1.0mL cryogenic vial

1,080g

EFC-35-CCT15

ColdBlockTM without temp. indicator for 35 x 1.5mL conical centrifuge tube

1,080g

EFC-35-CCT2

ColdBlockTM without temp. indicator for 35 x 2.0mL conical centrifuge tube

1,080g

Displaying CoolEnergizer_4 degree.pngDisplaying CoolEnergizer_minus 20.png

Submit a Review...